Roof Inspection Check List

10-Year Roof Inspection: 45-Point Checklist

Asphalt Shingle • MCSquared Roofing • Always Dry Limited Lifetime Workmanship Warranty

myroofer.com
336-988-ROOF
Legend & Drone Notes
[OK] Item inspected; no action needed   •   [A] Action required (repair/replace/adjust/clean)   •   [P#] Photo reference number (e.g., [P14])
Nadir = straight-down drone photos. Oblique = angled drone photos (~25–45°). Tip: one nadir pass + an oblique orbit; prioritize chimneys, skylights, sidewalls, transitions.
A. Safety & Structure (5)
#Inspection Item[OK][A][P#]Notes
1Ridge line straightness (no dips/sags)
2Decking firmness underfoot (no spongy areas)
3Truss/rafter movement or splits visible from attic
4Roof planes shed water to eaves (no ponding at dead valleys)
5Drone overview (nadir + oblique) of all elevations/planes; annotate defects
B. Shingles & Surface (9)
#Inspection Item[OK][A][P#]Notes
6Missing/loose shingles
7Curling or cupping edges
8Granule loss/bald spots
9Blistering or thermal cracking
10Nail pops/high nails
11Exposed fiberglass mat
12Organic growth (algae/moss/lichen)
13Course alignment/reveals consistent
14Eave overhang 1/4"–3/4" (note deviations)
C. Valleys & Rakes (4)
#Inspection Item[OK][A][P#]Notes
15Valley type documented; general condition
16Closed-cut / woven cut line straight; no bridging/voids
17Metal valley: rust, pinholes, loose fasteners
18Rake edge secure; starter coverage proper
D. Flashings (6)
#Inspection Item[OK][A][P#]Notes
19Step flashing interlaced at sidewalls (not caulk-dependent)
20Apron/headwall flashing secured and sealed
21Kick-out flashing present and properly angled
22Chimney step/counter flashing tight; mortar/crown intact
23Skylight perimeter flashing intact (no tar fixes)
24Exposed fastener heads on metal trims sealed
E. Penetrations & Accessories (6)
#Inspection Item[OK][A][P#]Notes
25Pipe boots pliable; no hairline cracks
26Vent hoods/box vents secured; screens intact
27Attic/power fan housing and shroud intact
28Satellite/antenna mounts flashed and structurally sound
29Ridge vent fasteners seated; cap shingles intact
30Abandoned penetrations properly plated/flashed
F. Gutters, Fascia, Soffit (6)
#Inspection Item[OK][A][P#]Notes
31Gutters free of debris and heavy granules
32Proper slope; no standing water
33Hangers tight; corners/miters/seams not leaking
34Downspouts secured; discharge 4–6 ft from foundation
35Fascia/soffit: no rot, staining, animal/insect activity
36Continuous drip edge under shingles and over gutter
G. Attic: Ventilation & Insulation (6)
#Inspection Item[OK][A][P#]Notes
37Decking underside: stains, mold, delamination
38Soffit intake clear; baffles present where needed
39Exhaust type/count adequate; intake-to-exhaust balance
40Condensation signs on nails/sheathing
41Insulation depth/coverage uniform
42Moisture/dampness noted or meter reading logged
H. Storm/Damage Screen (3)
#Inspection Item[OK][A][P#]Notes
43Hail indicators (bruising, displaced granules with mat exposure)
44Wind uplift/unsealed or creased tabs
45Limb/debris impact marks
Maintenance Performed Today (10-Year Tune-Up)
Findings Summary
Scope notes: Applies to asphalt shingle roofs within our NC service counties. Structural carpentry, siding removal for kick-outs, skylight replacements, and decking repairs are outside this checklist and quoted separately.
GIVE US A CALL